EG-UPS-002

UPS with AVR, 850 VA

  • ULTIMATE DEFENCE
  • Table top design
  • Provides backup power - prevents data loss
  • Protects your sensitive and valuable equipment
  • Compact and reliable - ideal for home and small office use

 

 

pecifiche Tecniche
Type: line interactive
Waveform: sine wave (AC mains), modified (square) sine wave (battery)
Input: 220 V AC ± 25%, 50 / 60 Hz ± 10%
Output: 220 V AC ± 10%, 50 / 60 Hz ± 1% (220 V AC ± 5 % at inverter mode)
Switching time: less than 10 ms
Backup time: 10...30 mins (depends on the load)
Battery: 151 x 65 x 95 mm, sealed lead-acid 12 V DC / 8Ah
Charge time: up to 8 hours
Sockets: 1 x C13 (input), cable CEE 7/7P, 4 x Schuko (output)
Sockets with UPS backup: 2 pcs
Operating conditions: 0°C~40°C, at humidity 20~90%RH non condensing
Power: 850 VA (510 W)
Charging current: up to 1.2 A
Noise: < 45 dB at 1 m distance
Dimensions: 280 x 185 x 95 mm
Product weight: 5.6 kg
"Cold-start" function

 

Requisiti di sistema
In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work.

 

 

EG-UPS-002

UPS with AVR, 850 VA

  • ULTIMATE DEFENCE
  • Table top design
  • Provides backup power - prevents data loss
  • Protects your sensitive and valuable equipment
  • Compact and reliable - ideal for home and small office use

 

 

pecifiche Tecniche
Type: line interactive
Waveform: sine wave (AC mains), modified (square) sine wave (battery)
Input: 220 V AC ± 25%, 50 / 60 Hz ± 10%
Output: 220 V AC ± 10%, 50 / 60 Hz ± 1% (220 V AC ± 5 % at inverter mode)
Switching time: less than 10 ms
Backup time: 10...30 mins (depends on the load)
Battery: 151 x 65 x 95 mm, sealed lead-acid 12 V DC / 8Ah
Charge time: up to 8 hours
Sockets: 1 x C13 (input), cable CEE 7/7P, 4 x Schuko (output)
Sockets with UPS backup: 2 pcs
Operating conditions: 0°C~40°C, at humidity 20~90%RH non condensing
Power: 850 VA (510 W)
Charging current: up to 1.2 A
Noise: < 45 dB at 1 m distance
Dimensions: 280 x 185 x 95 mm
Product weight: 5.6 kg
"Cold-start" function

 

Requisiti di sistema
In order to work correclty, the connected load should be at least 5% of the maximum capacity of the UPS. For example, a 700 W UPS needs at least a connected load of 35 W to work.

 